Kenics
Heat Exchangers
Kenics® Static Mixer technology, available exclusively in Kenics® Heat Exchangers, offers the highest available coefficients for fast, uniform
heat transfer. Capable of reliable operation in a wide range of process
applications, including those in the polymer, plastic, and food and beverage
industries, Kenics Heat Exchangers require less space, less energy and less
residence time than standard designs.
Static Mixing Element Technology
The Kenics Heat Exchanger consists of a continuous string of static mixer
elements within each heat exchanger tube. Fluid flow is directed radially toward
the pipe walls and back to the element, regardless of velocity. Additionally,
momentum reversal and flow division also contributes to the mixing efficiency.
All processed material is continuously and completely intermixed to eliminate
radial gradients in temperature, velocity and material composition. As a result, Kenics Heat Exchangers provide predictable, controlled mixing, and the most
efficient form of thermal transfer available today.
Efficient Heat Exchanger Design
By using Kenics Static Mixer elements in each
heat exchanger tube, the film build-up commonly associated with empty tubes is
significantly reduced. Process fluid is continuously pushed from the center of
each tube, to the wall and back to the center, eliminating thermal gradients and
boosting the inside film coefficient.
Kenics Static Mixer elements produce a more
uniform, consistent transfer process, with three to seven times greater heat
transfer rates than empty tubes alone. Other characteristics include the
following:
- Mixer elements create self-cleaning
wiping action
- Plug flow characteristics produce
uniform heat history
- Temperature gradients are blended
out
|
- Minimal fouling
- Surface renewal at tube wall
reduces chance of thermal degradation
- Viscous materials can cool to near
freezing
|
Kenics Static Mixer elements are furnace brazed to the pipe walls. The resultant
enhanced surface area and internal fin effect augment the mixing action to
dramatically enhance transfer rates. Removable elements are also available for
applications requiring periodic cleaning during product change-over.
Advanced Design and Fabrication
As custom-built, individually crafted units, Kenics Heat Exchangers are built to stringent ASME and TEMA codes, requiring the
use of efficient, state-of-the-art equipment in both design and manufacturing
operations. Often large and complex, these units require considerable welding
and metal joining. Using the most advanced welding techniques and tools
available, fabrication specialists produce a smooth, uniform weld at each tube
end. |